Page 1 - Rack Mount Server

User’s ManualGS-SR125EDL Rack Mount ServerDual XeonTM Processor Motherboard / Server SolutionRev. 100125A08-05EDL-C00

Page 2 - Table of Content

10GS-SR125EDL Rack mount ServerIntegrated Super I/O:Serial Ports — 1 x Serial Port COM1 (Rear I/O-Shield)— 1 x Serial Port COM2 (Front I/O Shield)— Bo

Page 3

11Hardware Installation ProcessChapter 2 System Hardware InstallationPlease observe the safety information in chapter ¡§ Important Safety Information¡

Page 4 - Network Options

12GS-SR125EDL Rack mount ServerStep 3Step 2-3: Heat Sink InstallationStep 1 To install the heat sink, just simply put it on the retention module.Step

Page 5

13Hardware Installation ProcessStep 2-5: PCI Expansion Card InstallationGS-SR125EDL provides expansion riser slots for two peripheral cards, 100/133MH

Page 6

14GS-SR125EDL Rack mount ServerStep 5Step 2-6: Hard Disk Drive InstallationStep 1 Pull the hard disk drive tray handle and remove the tray from the ch

Page 7

15Hardware Installation ProcessStep 2-8: Reinstall Top CoverStep 1 Gently apply force to the indentures with your thumbs and push toward the chassis (

Page 8 - WARNING!

16GS-SR125EDL Rack mount Server3-1: Front View of GS-SR125EDLChapter 3 Appearance of GS-SR125EDLuvwxxwvuIDE HDDUSB ConnectorsSystem LEDCD-ROM Disk

Page 9 - Chapter 1 Features Summary

System Appearance173-2: Rear View of GS-SR125EDLxz{uvy|wPS/2 Keyboard & Mouse ConnectorLow ProfileFull-Height / Full- LengthLAN 1 / 2 PortsVGA Por

Page 10 - GS-SR125EDL Rack mount Server

18GS-SR125EDL Rack mount Server3-3: IDE Backplane Layout and DescriptionABCEDFGHIJKQPOMNLTUSRVWXA ,C ,D Power G FAN9F , HFAN1IFAN10K , JFAN2RIDE1M ,

Page 11 - Step 2-2: CPU Installation

19LED Description3-4: Switch and LED Indicators DescriptionActing Color Status Power LED On Green Pow er OnOn Amber Pow er cable is plugged inBlink Gr

Page 12 - Step 2-4: Memory Installation

2GS-SR125EDL Rack mount ServerTable of ContentSafety, Care and Regulatory Information ... 4Introduction ...

Page 13 - Hardware Installation Process

20GS-SR125EDL Rack mount Server3-5: HDD LED Indicators DescriptionHDD LED 1HDD LED 2Acting Color StatusHDD LED 1 Off N/A HDD power offHDD LED 1 On Gre

Page 14

21Connector Icon Description3-6 : Connector Icon DescriptionSuggest Icon DescriptionKeyboardVGAMouseLANParallel PortSerial PortUSB

Page 15 - Step 2-8: Reinstall Top Cover

22GS-SR125EDL Rack mount ServerChapter 4 Motherboard Layout & Jumper SettingIntroductionGA-8EGPDRE Motherboard Layout1 23451412161513101819202123

Page 16

23Connector and Jumper Setting IntroductionGA-8EGPDRE Motherboard Layout Description1CPU2(Install First)23 WOM12 CPU1 24 PWRDET13 CMIC-SL 25 SMBUS14

Page 17 - System Appearance

24GS-SR125EDL Rack mount Server 13) BT1 (Battery) Li-Battery 3V 14 / 15 / 16) SYS_FAN1/2/3 (System Fan Connector)1Pin No. Definition1 GND2 +12v/Contro

Page 18

25Connector and Jumper Setting Introduction 17 / 18) CPU_FAN1/2 (CPU Fan Connector)CPU_FAN1CPU_FAN2ØPlease note, a proper installation of the CPUcoole

Page 19

26GS-SR125EDL Rack mount Server 20 / 21) IPMB1/ IPMB 2 (IPMB Connector)1Pin No. Definition1 SCl_IPMB2 GND3 SDA_IPMB22) WOL1 (Wake on LAN Connector)Pin

Page 20 - HDD LED 2

27Connector and Jumper Setting Introduction23) WOM1 (Wake on Modem Connector)1Pin No. Definition1 Signal2 GND24) PWRDET1 (Power Status Interface)Pin D

Page 21 - Suggest Icon Description

28GS-SR125EDL Rack mount Server25 / 26) SMBUS1 / 2 (SMBUS Connectors)Pin Definition1 VCC2 SDA3 SCL4 NC5 GNDSMBUS1SMBUS2127) FFC1 (IPMB I2C Bus Connect

Page 22

29Connector and Jumper Setting Introduction28 / 29) PCIX_SLOT2 / PCI64_SLOT(PCI Slots)PCIX_SLOT2PCI64_SLOTPCIX_SLOT2:Supports full-height/full-length

Page 23

3Table of ContentCache Memory ... 41I/O Device Configuration ...

Page 24 - 13) BT1 (Battery)

30GS-SR125EDL Rack mount Server34) FDD1 (Floppy Connector)Please connect the floppy drive ribbon cables to FDD. It supports 360K,720K,1.2M,1.44M and2.

Page 25

31Connector and Jumper Setting Introduction 43) JP9 (PCI_SLOT1 Bus Speed Functon)111-2 close: Conventional PCI Mode2-3 close: PCI-X 66MHz(Default)Ope

Page 26

32GS-SR125EDL Rack mount Server<á> Move to previous item<â> Move to next item<ß> Move to the item in the left hand<à> Move to

Page 27

33BIOS Setupl MainThis setup page includes all the items in standard compatible BIOS.l AdvancedThis setup page includes all the items of AMI special e

Page 28

34GS-SR125EDL Rack mount ServerC System Time The time is calculated based on the 24-hour military time clock. Set the System Time (HH:MM:SS)C System D

Page 29

35BIOS SetupC Legacy Diskette A This category identifies the type of floppy disk drive A that has been installed in the computer.8None No flopp

Page 30 - 34) FDD1 (Floppy Connector)

36GS-SR125EDL Rack mount Server8 Multi-Sector TransferThis field displays the information of Multi-Sector Transfer Mode.Disabled: The data transfer fr

Page 31

37BIOS SetupFigure 2: AdvancedPhoenixBIOS Setup UtilityMain Advanced Security Boot Exit} Advanced Processor Option It

Page 32 - Chapter 5 BIOS Setup

38GS-SR125EDL Rack mount ServerCAdvanced Processor Option4 Fast String OperationsSet the CPU fast string features.8 Enabled Enable CPU fast string fe

Page 33

39BIOS SetupFigure 2-2: PCI ConfigurationPhoenixBIOS Setup Utility AdvancedPCI Configuration Item Specific HelpPCI/PNP ISA UMB Region ExclusionP

Page 34 - “ø ”Indicates DISPLAY ONLY

4GS-SR125EDL Rack mount ServerSafety, Care and Regulatory InformationL Important safety informationRead and follow all instructions marked on the prod

Page 35 - GNote: The 1.25MB,3

40GS-SR125EDL Rack mount ServerFigure 2-3: Cache MemoryPhoenixBIOS Setup Utility AdvancedCache Memory Item Specific Help} Memory Cache [Enabled]

Page 36 - CBIOS version

41BIOS Setup4 Cache System BIOS areaControls caching of System BIOS area.8 Uncached System BIOS area is uncached.8 Write Protect Write/Saved settings

Page 37 - Advanced

42GS-SR125EDL Rack mount ServerCI/O Device Configuration4 Serial Port A This allows users to configure serial prot A by using this option.8Disabled D

Page 38 - Advanced Processor Option

43BIOS Setup4 Floppy Disk Controller Enable and disable the function of floppy disk controller.8Disabled Disable the configuration.8Enabled Enable

Page 39 - PCI Configuration

44GS-SR125EDL Rack mount ServerFigure 2-5: Console RedirectionPhoenixBIOS Setup Utility AdvancedConsole Redirection Item Specific HelpCOM Port A

Page 40 - Cache Memory

45BIOS Setup4 Baud RateEnable the specified of C. R Port Baud Rate.8300 Enable the specific baud rate at 300.81200 Enable the specific baud rate at 12

Page 41

46GS-SR125EDL Rack mount Server4 Continue C.R after POSTEnable Console Redirection after O.S has loaded8On Continue C.R after Power on Self Test.8Off

Page 42 - I/O Device Configuration

47BIOS SetupSecurityFigure 3: SecurityPhoenixBIOS Setup UtilityMain Advanced Security Boot ExitSet User Password [Ent

Page 43 - CSystem After AC Back

48GS-SR125EDL Rack mount ServerCSet Supervisor PasswordYou can install and change this options for the setup menus. Type the password up to 6character

Page 44 - Console Redirection

49BIOS SetupBootFigure 4: BootPhoenixBIOS Setup UtilityMain Advanced Security Boot Exit+ Removable Device Item Specif

Page 45

5Safety Information* To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.* Do not plug a modem or telephone cable i

Page 46

50GS-SR125EDL Rack mount ServerExitFigure 5: ExitPhoenixBIOS Setup UtilityMain Advanced Security Boot ExitExit Saving

Page 47 - Security

51BIOS SetupCExit Discarding ChangesThis option allows user to exit system setup without changing anyprevious settings values in CMOS. The previous se

Page 48 - CSystem backup reminder

52GS-SR125EDL Rack mount ServerAcronyms MeaningACPI Advanced Configuration and Power InterfaceAPM Advanced Power ManagementAGP Accelerated Graphics Po

Page 49 - CBoot Device Priority

53BIOS SetupAcronyms MeaningI/O Input / OutputIOAPIC Input Output Advanced Programmable Input ControllerISA Industry Standard ArchitectureLAN Local Ar

Page 50

6GS-SR125EDL Rack mount ServerYour telephone company may make changes in its facilities, equipment, operations, or procedures thatcould affect proper

Page 51

7Safety InformationNOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the totalload to be connected to a telephon

Page 52 - Chapter 6 Appendix

8GS-SR125EDL Rack mount Serverþ Chassis þ Power Supply (Installed)þ The 8EGPDRE Motherboard þ Silm ype CD-ROM drive (Installed)þ Two CPU Heat Sinks þ

Page 53

9Feature SummaryMotherboard — GA-8EGPDREProcessor Supported — Dual socket 604 for Intel® FC-PGA XeonTM processor suopprtsup to 3.06GB— Intel® Xeon 5

Commentaires sur ces manuels

Pas de commentaire